RKC REX-C100 REX-C100FK02-M*AN DA Digital PID Temperature Control Controller Thermostat Relay Output K Type Input AC110-240V

RKC REX-C100 REX-C100FK02-M*AN DA Digital PID Temperature Control Controller Thermostat Relay Output K Type Input AC110-240V SUPPLIER BANGLADESH PRICE BANGLADESH IMPORTER BANGLADESH BD

 

 

 

The REX-C100 PID temperature controller has multiple parameters to fine-tune temperature control and alarm settings. Here’s a general overview of key parameters for the REX-C100FK02-M*AN DA model, which may vary slightly depending on the exact version.

Common Parameters and Their Descriptions

  1. SV (Set Value)
    • The target temperature you want to achieve.
  2. P (Proportional Band)
    • Controls the width of the proportional band. Lower values make the control more sensitive.
  3. I (Integral Time)
    • Adjusts the speed of response to eliminate residual steady-state error. Setting this to 0 disables the integral action.
  4. D (Derivative Time)
    • Adjusts the rate of reaction to sudden changes in temperature, reducing overshoot. Setting this to 0 disables the derivative action.
  5. Ctrl (Control Mode)
    • 0 for heating control, 1 for cooling control.
  6. AT (Auto-Tuning)
    • Set to ON to enable auto-tuning, which allows the controller to automatically set PID values.
  7. ALM1 and ALM2 (Alarm Settings)
    • Set points for triggering alarms based on temperature thresholds.
  8. Hy (Hysteresis)
    • The difference between ON and OFF points for controlling hysteresis in heating/cooling control.
  9. Sn (Sensor Type)
    • Defines the input sensor type. For example:
      • K for K-type thermocouple
      • J for J-type thermocouple, etc.
  10. Outy (Output Mode)
    • Sets the output type, usually relay or voltage pulse.
  11. dP (Decimal Point Position)
    • Sets the position of the decimal point for the temperature reading.
  12. Loc (Lock Setting)
    • Enables or disables parameter locking to prevent accidental changes.
  13. Adr (Address for Communication)
    • Sets the Modbus address for communication via RS-485 (if applicable).

Accessing and Adjusting Parameters

  1. Enter Parameter Setting Mode: Press and hold the SET button to access configuration mode.
  2. Select Parameter: Use the UP and DOWN buttons to scroll through parameters.
  3. Adjust Values: Press SET again to modify a parameter, then adjust with the UP and DOWN buttons.
  4. Confirm and Exit: Press and hold SET to confirm changes and exit the parameter setting mode.

 

 

 

 

 

 

 

RKC REX-C100 Series Models:
REX-C100FK02-V*AN
REX-C100FK02-V*MN
REX-C100FK02-V*EN
REX-C100FK02-V*UN
REX-C100FK07-M*AN
REX-C100FK07-M*EN
REX-C100FK07-M*MN
REX-C100FK07-M*UN
REX-C100CK02-V*AN
REX-C100CK02-V*MN
REX-C100CK02-V*EN
REX-C100CK02-V*UN
REX-C100CK07-M*AN
REX-C100CK07-M*MN
REX-C100CK07-M*EN
REX-C100CK07-M*UN

RKC REX-C400 Series Models:
REX-C400FK02-V*AN
REX-C400FK02-V*MN
REX-C400FK02-V*EN
REX-C400FK02-V*UN
REX-C400FK07-M*AN
REX-C400FK07-M*EN
REX-C400FK07-M*MN
REX-C400FK07-M*UN
REX-C400CK02-V*AN
REX-C400CK02-V*MN
REX-C400CK02-V*EN
REX-C400CK02-V*UN
REX-C400CK07-M*AN
REX-C400CK07-M*MN
REX-C400CK07-M*EN
REX-C400CK07-M*UN

RKC REX-C700 Series Models:
REX-C700FK02-V*AN
REX-C700FK02-V*MN
REX-C700FK02-V*EN
REX-C700FK02-V*UN
REX-C700FK07-M*AN
REX-C700FK07-M*EN
REX-C700FK07-M*MN
REX-C700FK07-M*UN
REX-C700CK02-V*AN
REX-C700CK02-V*MN
REX-C700CK02-V*EN
REX-C700CK02-V*UN
REX-C700CK07-M*AN
REX-C700CK07-M*MN
REX-C700CK07-M*EN
REX-C700CK07-M*UN

Add to Wishlist
Add to Wishlist
Category:

Description

RKC REX-C100 REX-C100FK02-M*AN DA Digital PID Temperature Control Controller Thermostat Relay Output K Type Input AC110-240V SUPPLIER BANGLADESH PRICE BANGLADESH IMPORTER BANGLADESH BD

 

 

 

The REX-C100 PID temperature controller has multiple parameters to fine-tune temperature control and alarm settings. Here’s a general overview of key parameters for the REX-C100FK02-M*AN DA model, which may vary slightly depending on the exact version.

Common Parameters and Their Descriptions

  1. SV (Set Value)
    • The target temperature you want to achieve.
  2. P (Proportional Band)
    • Controls the width of the proportional band. Lower values make the control more sensitive.
  3. I (Integral Time)
    • Adjusts the speed of response to eliminate residual steady-state error. Setting this to 0 disables the integral action.
  4. D (Derivative Time)
    • Adjusts the rate of reaction to sudden changes in temperature, reducing overshoot. Setting this to 0 disables the derivative action.
  5. Ctrl (Control Mode)
    • 0 for heating control, 1 for cooling control.
  6. AT (Auto-Tuning)
    • Set to ON to enable auto-tuning, which allows the controller to automatically set PID values.
  7. ALM1 and ALM2 (Alarm Settings)
    • Set points for triggering alarms based on temperature thresholds.
  8. Hy (Hysteresis)
    • The difference between ON and OFF points for controlling hysteresis in heating/cooling control.
  9. Sn (Sensor Type)
    • Defines the input sensor type. For example:
      • K for K-type thermocouple
      • J for J-type thermocouple, etc.
  10. Outy (Output Mode)
    • Sets the output type, usually relay or voltage pulse.
  11. dP (Decimal Point Position)
    • Sets the position of the decimal point for the temperature reading.
  12. Loc (Lock Setting)
    • Enables or disables parameter locking to prevent accidental changes.
  13. Adr (Address for Communication)
    • Sets the Modbus address for communication via RS-485 (if applicable).

Accessing and Adjusting Parameters

  1. Enter Parameter Setting Mode: Press and hold the SET button to access configuration mode.
  2. Select Parameter: Use the UP and DOWN buttons to scroll through parameters.
  3. Adjust Values: Press SET again to modify a parameter, then adjust with the UP and DOWN buttons.
  4. Confirm and Exit: Press and hold SET to confirm changes and exit the parameter setting mode.

 

 

 

 

 

 

 

RKC REX-C100 Series Models:
REX-C100FK02-V*AN
REX-C100FK02-V*MN
REX-C100FK02-V*EN
REX-C100FK02-V*UN
REX-C100FK07-M*AN
REX-C100FK07-M*EN
REX-C100FK07-M*MN
REX-C100FK07-M*UN
REX-C100CK02-V*AN
REX-C100CK02-V*MN
REX-C100CK02-V*EN
REX-C100CK02-V*UN
REX-C100CK07-M*AN
REX-C100CK07-M*MN
REX-C100CK07-M*EN
REX-C100CK07-M*UN

RKC REX-C400 Series Models:
REX-C400FK02-V*AN
REX-C400FK02-V*MN
REX-C400FK02-V*EN
REX-C400FK02-V*UN
REX-C400FK07-M*AN
REX-C400FK07-M*EN
REX-C400FK07-M*MN
REX-C400FK07-M*UN
REX-C400CK02-V*AN
REX-C400CK02-V*MN
REX-C400CK02-V*EN
REX-C400CK02-V*UN
REX-C400CK07-M*AN
REX-C400CK07-M*MN
REX-C400CK07-M*EN
REX-C400CK07-M*UN

RKC REX-C700 Series Models:
REX-C700FK02-V*AN
REX-C700FK02-V*MN
REX-C700FK02-V*EN
REX-C700FK02-V*UN
REX-C700FK07-M*AN
REX-C700FK07-M*EN
REX-C700FK07-M*MN
REX-C700FK07-M*UN
REX-C700CK02-V*AN
REX-C700CK02-V*MN
REX-C700CK02-V*EN
REX-C700CK02-V*UN
REX-C700CK07-M*AN
REX-C700CK07-M*MN
REX-C700CK07-M*EN
REX-C700CK07-M*UN

Reviews

There are no reviews yet.

Be the first to review “RKC REX-C100 REX-C100FK02-M*AN DA Digital PID Temperature Control Controller Thermostat Relay Output K Type Input AC110-240V”

Your email address will not be published. Required fields are marked *

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping
× Hello Dear How can I help you? 👦