Previous
Previous Product Image

Piab suction cup G.BGI41S50.B3.S1.G38M.00/9914064

Original price was: 999.00৳ .Current price is: 111.00৳ .
Next

Burkert Transmitter 8400 00444697

Original price was: 999.00৳ .Current price is: 111.00৳ .
Next Product Image

Burkert Conductivity Meter 8228 00570124

Original price was: 999.00৳ .Current price is: 111.00৳ .

Burkert Conductivity Meter 8228 00570124 Burkert supplier in Bangladesh bd importer in Bangladesh bd price in bd

The Burkert 8228 with part number 00570124 is a conductivity meter used for measuring the electrical conductivity of liquids. This type of meter is crucial in various industrial applications, including water treatment, chemical processing, and food production, where monitoring the ionic content of a liquid is essential for process control and quality assurance.

Key Details and Features of the Burkert 8228 Conductivity Meter (00570124)

  1. Measurement Principle:
    • Conductivity Measurement: The meter measures the ability of a liquid to conduct electrical current, which correlates with the concentration of ions in the solution.
  2. Electrode Compatibility:
    • The 8228 is designed to work with specific conductivity sensors or electrodes. The sensors typically have platinum electrodes or similar materials designed to ensure accurate measurements in various conditions.
  3. Output Signals:
    • Analog Output: Provides standard signals such as 4-20 mA or 0-10 V for integration with process control systems.
    • Digital Communication: May include options like HART protocol or other digital interfaces for communication with control systems or data loggers.
  4. Display and Interface:
    • Display: Often equipped with an LCD or LED display for real-time measurement readouts and system status.
    • User Interface: Allows for calibration, configuration, and adjustment of measurement parameters. This may include buttons or a touchscreen interface.
  5. Calibration:
    • The meter typically supports calibration with standard solutions to ensure accuracy. Calibration procedures and intervals will be detailed in the product documentation.
  6. Enclosure and Mounting:
    • Enclosure: Designed to withstand industrial environments, often with an IP rating for protection against dust and moisture.
    • Mounting: Options may include panel mounting or wall mounting, depending on the installation requirements.
  7. Power Supply:
    • Voltage Requirements: The meter will require a specific power supply, often 24 VDC or another standard voltage. The exact requirements will be specified in the datasheet.
  8. Temperature Compensation:
    • Many conductivity meters include automatic temperature compensation to adjust readings based on the temperature of the liquid being measured.
  9. Application:
    • Suitable for a wide range of applications including water treatment, chemical processes, food and beverage industry, and more.
Add to Wishlist
Add to Wishlist
Category:

Description

Burkert Conductivity Meter 8228 00570124 Burkert supplier in Bangladesh bd importer in Bangladesh bd price in bd

The Burkert 8228 with part number 00570124 is a conductivity meter used for measuring the electrical conductivity of liquids. This type of meter is crucial in various industrial applications, including water treatment, chemical processing, and food production, where monitoring the ionic content of a liquid is essential for process control and quality assurance.

Key Details and Features of the Burkert 8228 Conductivity Meter (00570124)

  1. Measurement Principle:
    • Conductivity Measurement: The meter measures the ability of a liquid to conduct electrical current, which correlates with the concentration of ions in the solution.
  2. Electrode Compatibility:
    • The 8228 is designed to work with specific conductivity sensors or electrodes. The sensors typically have platinum electrodes or similar materials designed to ensure accurate measurements in various conditions.
  3. Output Signals:
    • Analog Output: Provides standard signals such as 4-20 mA or 0-10 V for integration with process control systems.
    • Digital Communication: May include options like HART protocol or other digital interfaces for communication with control systems or data loggers.
  4. Display and Interface:
    • Display: Often equipped with an LCD or LED display for real-time measurement readouts and system status.
    • User Interface: Allows for calibration, configuration, and adjustment of measurement parameters. This may include buttons or a touchscreen interface.
  5. Calibration:
    • The meter typically supports calibration with standard solutions to ensure accuracy. Calibration procedures and intervals will be detailed in the product documentation.
  6. Enclosure and Mounting:
    • Enclosure: Designed to withstand industrial environments, often with an IP rating for protection against dust and moisture.
    • Mounting: Options may include panel mounting or wall mounting, depending on the installation requirements.
  7. Power Supply:
    • Voltage Requirements: The meter will require a specific power supply, often 24 VDC or another standard voltage. The exact requirements will be specified in the datasheet.
  8. Temperature Compensation:
    • Many conductivity meters include automatic temperature compensation to adjust readings based on the temperature of the liquid being measured.
  9. Application:
    • Suitable for a wide range of applications including water treatment, chemical processes, food and beverage industry, and more.