Pilz 751177 PNOZ s7.2 C 24VDC 4 n/o 1 n/c Pilz supplier in Bangladesh bd importer in Bangladesh bd price in bd
The Pilz PNOZ s7.2 C 24VDC 4 n/o 1 n/c is a model of a safety relay from Pilz’s PNOZ series, specifically designed for safety applications in industrial automation. Here’s a detailed breakdown of its specifications and features:
Key Specifications and Features
- Safety Functionality:
- Safety Category: Conforms to safety categories such as Category 4 according to ISO 13849-1, providing high safety integrity for critical safety functions.
- Safety Integrity Level (SIL): Meets SIL 3 requirements according to IEC 61508, suitable for highly safety-critical applications.
- Inputs and Outputs:
- Input Voltage: Operates at a control voltage of 24 VDC (Direct Current), which is common in industrial control systems.
- Relay Outputs:
- 4 Normally Open (n/o): These outputs close when the relay is activated and are used for signaling or controlling external devices or machinery.
- 1 Normally Closed (n/c): This output opens when the relay is activated and is typically used for safety circuits where you need to ensure that a safety function is deactivated when the relay is not active.
- Design and Configuration:
- DIN Rail Mounting: Designed for easy installation on DIN rails, which is a standard mounting method in control cabinets.
- Compact Size: Designed to be space-efficient while providing reliable safety functions.
- Status Indication: Includes LED indicators to show the status of the relay, including operational status and fault conditions.
- Diagnostic and Monitoring:
- Diagnostics: Equipped with diagnostic features to assist with fault detection and troubleshooting.
- Monitoring: Continuously monitors the safety functions to ensure reliable operation and compliance with safety standards.
- Applications:
- Emergency Stop Circuits: Used to manage emergency stop functions to ensure machinery can be quickly stopped in emergency situations.
- Safety Interlocks: Controls safety interlocks such as safety doors or guards to prevent machinery operation while safety doors are open.
- General Safety Monitoring: Suitable for a variety of safety monitoring applications where reliable and compliant safety control is required.
Installation and Usage
- Wiring: Follow the wiring diagrams provided in the product documentation to connect the relay to your safety devices and circuits correctly.
- Configuration: Configure the relay according to your specific safety requirements, ensuring correct connections to safety devices and outputs.
- Testing: After installation, perform thorough testing to ensure the relay operates correctly and meets all required safety standards.