RKC REX-C100 REX-C100FK02-M*AN DA Digital PID Temperature Control Controller Thermostat Relay Output K Type Input AC110-240V SUPPLIER BANGLADESH PRICE BANGLADESH IMPORTER BANGLADESH BD
The REX-C100 PID temperature controller has multiple parameters to fine-tune temperature control and alarm settings. Here’s a general overview of key parameters for the REX-C100FK02-M*AN DA model, which may vary slightly depending on the exact version.
Common Parameters and Their Descriptions
- SV (Set Value)
- The target temperature you want to achieve.
- P (Proportional Band)
- Controls the width of the proportional band. Lower values make the control more sensitive.
- I (Integral Time)
- Adjusts the speed of response to eliminate residual steady-state error. Setting this to 0 disables the integral action.
- D (Derivative Time)
- Adjusts the rate of reaction to sudden changes in temperature, reducing overshoot. Setting this to 0 disables the derivative action.
- Ctrl (Control Mode)
- 0 for heating control, 1 for cooling control.
- AT (Auto-Tuning)
- Set to ON to enable auto-tuning, which allows the controller to automatically set PID values.
- ALM1 and ALM2 (Alarm Settings)
- Set points for triggering alarms based on temperature thresholds.
- Hy (Hysteresis)
- The difference between ON and OFF points for controlling hysteresis in heating/cooling control.
- Sn (Sensor Type)
- Defines the input sensor type. For example:
- K for K-type thermocouple
- J for J-type thermocouple, etc.
- Defines the input sensor type. For example:
- Outy (Output Mode)
- Sets the output type, usually relay or voltage pulse.
- dP (Decimal Point Position)
- Sets the position of the decimal point for the temperature reading.
- Loc (Lock Setting)
- Enables or disables parameter locking to prevent accidental changes.
- Adr (Address for Communication)
- Sets the Modbus address for communication via RS-485 (if applicable).
Accessing and Adjusting Parameters
- Enter Parameter Setting Mode: Press and hold the SET button to access configuration mode.
- Select Parameter: Use the UP and DOWN buttons to scroll through parameters.
- Adjust Values: Press SET again to modify a parameter, then adjust with the UP and DOWN buttons.
- Confirm and Exit: Press and hold SET to confirm changes and exit the parameter setting mode.
RKC REX-C100 Series Models:
REX-C100FK02-V*AN
REX-C100FK02-V*MN
REX-C100FK02-V*EN
REX-C100FK02-V*UN
REX-C100FK07-M*AN
REX-C100FK07-M*EN
REX-C100FK07-M*MN
REX-C100FK07-M*UN
REX-C100CK02-V*AN
REX-C100CK02-V*MN
REX-C100CK02-V*EN
REX-C100CK02-V*UN
REX-C100CK07-M*AN
REX-C100CK07-M*MN
REX-C100CK07-M*EN
REX-C100CK07-M*UN
RKC REX-C400 Series Models:
REX-C400FK02-V*AN
REX-C400FK02-V*MN
REX-C400FK02-V*EN
REX-C400FK02-V*UN
REX-C400FK07-M*AN
REX-C400FK07-M*EN
REX-C400FK07-M*MN
REX-C400FK07-M*UN
REX-C400CK02-V*AN
REX-C400CK02-V*MN
REX-C400CK02-V*EN
REX-C400CK02-V*UN
REX-C400CK07-M*AN
REX-C400CK07-M*MN
REX-C400CK07-M*EN
REX-C400CK07-M*UN
RKC REX-C700 Series Models:
REX-C700FK02-V*AN
REX-C700FK02-V*MN
REX-C700FK02-V*EN
REX-C700FK02-V*UN
REX-C700FK07-M*AN
REX-C700FK07-M*EN
REX-C700FK07-M*MN
REX-C700FK07-M*UN
REX-C700CK02-V*AN
REX-C700CK02-V*MN
REX-C700CK02-V*EN
REX-C700CK02-V*UN
REX-C700CK07-M*AN
REX-C700CK07-M*MN
REX-C700CK07-M*EN
REX-C700CK07-M*UN